You are currently viewing The Fundamentals of Wet Riser System Design

The Fundamentals of Wet Riser System Design

Wet Riser Systems: Information & Considerations

Designing a wet riser system requires precise planning and attention to detail. From the positioning of each component to the necessary clearances and material selections, this guide provides invaluable information about wet riser systems for any project.

Understand Building Requirements.

Understanding the fire protection requirements of your building is essential when designing a wet riser system. Consider factors such as fire line pressure, the size and type of hose reels required, and any other specific needs that may be in effect within the building. It is also important to consult with all relevant stakeholders to ensure that safety guidelines are met and that no features have been overlooked.

Environmental considerations are just as important as safety requirements when devising a wet riser system. Buildings that experience extreme temperatures should be equipped with riser systems (Dry Riser System) that can maintain a constant temperature and avoid burst fixtures, while other structures may need specifications that prevent too much water from rushing through the system at once. Consulting with an experienced fire engineer will help to ensure that all elements of the building’s design are in compliance with the necessary standards and regulations.

Establish the Fire Flow Requirement.

One of the most important steps when designing a wet riser system is to determine your fire flow requirement. Fire flow is the amount of water required to suppress a fire, and it will depend on the particular circumstances of your building. Consult with local fire codes and regulations in order to correctly calculate this figure, as well as any additional requirements like hose reels or other special equipment.

The fire flow requirement will determine the size and layout of your wet riser system, as a certain amount of pumping capacity is necessary to provide the required flow in an emergency. It also impacts the design of the piping systems, selecting risers and branches of appropriate sizes based on local code requirements, so that enough water can be delivered to all areas in a timely manner during a fire event. Furthermore, other considerations like egress points for personnel or materials must be evaluated in order to develop a comprehensive design that meets the needs of your particular building.

Sizing Fire Pumps & Connections.

Once you know your fire flow requirement, the next step is to size your system. This includes determining the size of pumps and connections that will be required in order to meet this requirement. The rules of thumb for sizing a pump vary depending on local requirements; however, generally speaking, a good guide would be to select a pump with a discharge rate 15-20% higher than the total maximum fire flow required. Additionally, remember to factor in things like elevation differences when selecting pipes and connections.

It is important to factor in head pressure when calculating the total water flow rate. This can be done by measuring static head and sprinkler pipe manufacturer’s data. Once you know the maximum dynamic fire flow rate, select an appropriate pump size that is 15-20% higher than this figure. Additionally, when calculating what size of pipes and connections are needed for the system can be determined using a number of methods such as the Hazen – Williams law or the Manning equation, which factors in variables such as friction losses, elevation changes and pipe roughness. By ensuring proper sizing of your wet riser system components you can be sure that your firefighting teams have all the pressure they need to successfully put out any fires.

Choosing Control Valves & System Circuits.

Once you’ve determined the location of your dry riser inlet and outlet, it’s then time to lay out the circuits for your system. This includes choosing the appropriate control valves and overhead sprinklers throughout the entire building. Control valves should be carefully chosen based on several factors, such as the material being used, pressure drop, flow rate, and size of the pipe. Overhead sprinklers should also be selected to meet certain fire rating requirements depending on your local codes and regulations.

When laying out the system circuits, it is important to be aware of any potential water pressure loss due to the length and number of branches in your riser design. The valves should also be spaced at appropriate intervals throughout the building in order to reduce noise while helping promote uniform water distribution. Finally, all components of the wet riser system should be tested during a routine pressure flow test before they are officially commissioned.

Fire & Rescue Connections for Wet Risers.

After the wet riser has been properly laid out and its other components have been installed, you’ll need to connect a fire department connection. The fire department connection typically involves installing a standpipe outlet (Fire Hydrants) on the primary riser pipe and a female polished brass fitting at the property line. This allows for easy access by firefighters when they arrive on the scene, allowing them to quickly get water from outside sources into an interior space.

The connections for wet risers can be a bit complicated and should always be handled by a professional. The process generally includes cutting into the pipes to create openings, connecting them with couplers, and then welding the new components together. It’s also important to have a union or flange connecting the primary and secondary riser lines so they can easily be connected to a standpipe at the property line. Making sure your wet riser system is set up correctly is essential not only for proper functioning but also for meeting local fire codes in your area.

Testing and Commissioning a wet riser system

Testing and Commissioning a wet riser system can be a complicated process. The testing of the wet riser system involves checking the pressure, flow rate, temperature, and other parameters of the primary circuit. These tests need to be conducted at every level of the building for which the wet riser system is installed.

The commissioning process involves testing all components of the wet riser system after it has been installed in order to ensure that it operates as intended. This includes checking that all valves are functioning properly and that there are no leaks or other problems with the system.

Wet risers are a critical and often overlooked component of a fire sprinkler system. Choosing and installing the correct risers for your project can be one of the most important decisions you make when designing and maintaining a sprinkler system.

Have any questions regarding any aspect of this article please don’t hesitate to contact the Complete Fire and Pumps team, your local foire protection experts!